This DR Digital X-ray Imaging System is a high-performance, user-friendly medical device designed for the examination and diagnosis of human limbs. It is ideal for use in hospitals, clinics, physical examination centers, ambulances, and other medical facilities. Featuring a simple structure, compact size, and lightweight design, it does not require specific environmental conditions or a lead-shielded darkroom, making it highly versatile and easy to deploy in various settings.
Equipped with a flexible mobile stand, the system can easily adapt to different workstation requirements and can also be used for bedside imaging in hospital wards, offering enhanced convenience for medical staff and patients. The system provides three exposure control methods: remote control, hand switch, and touch screen, ensuring easy operation and versatility. Additionally, it includes fault self-protection and self-diagnosis features, as well as high-precision control of tube voltage and tube current, ensuring stable and reliable imaging quality.
$1,695.00
This DR Digital X-ray Imaging System is a high-performance, user-friendly medical device designed for the examination and diagnosis of human limbs. It is ideal for use in hospitals, clinics, physical examination centers, ambulances, and other medical facilities. Featuring a simple structure, compact size, and lightweight design, it does not require specific environmental conditions or a lead-shielded darkroom, making it highly versatile and easy to deploy in various settings.
Equipped with a flexible mobile stand, the system can easily adapt to different workstation requirements and can also be used for bedside imaging in hospital wards, offering enhanced convenience for medical staff and patients. The system provides three exposure control methods: remote control, hand switch, and touch screen, ensuring easy operation and versatility. Additionally, it includes fault self-protection and self-diagnosis features, as well as high-precision control of tube voltage and tube current, ensuring stable and reliable imaging quality.
-It can be widely used in the examination and diagnosis of human limbs, and is suitable for medical institutions such as hospitals, clinics, physical examination centers, ambulances, etc;
-Simple structure, small size, light weight, no environmental restrictions, no need to build a lead shielded darkroom;
-Mobile rack is flexible and convenient, which can meet the requirements of different workstations, and can be used as a bedside shooting in a hospital ward;
-Three exposure control methods: remote control, hand switch, touch screen;
-Fault self-protection, self-diagnosis, high-precision control of tube voltage and tube current;
-It is a DR digital X-ray photography system.
Technical Specifications
| General Parameter | ||||
| Model: | QMDR-50 | QMDR-53 | QMDR-56 | QMDR-80 |
| Output Power | 5kW | 5.3kW | 5.6kW | 8kW |
| Rated Voltage | 220~240VAC | 220~240VAC | 220~240VAC | 220VAC ,±10%, 50Hz |
| Inverter Frequency | 100kHz±10% | 100kHz±10% | 100kHz±10% | 100kHz±5% |
| kV accuracy | ±10% | ±10% | ±10% | ±4% |
| mA accuracy | ±10% | ±10% | ±10% | ≤±(5% ) (mA>25mA,ms>5); ≤±(10% +1mA) (mA≤25mA); |
| Rotor | Fixed anode | Fixed anode | Fixed anode | Fixed anode |
| Exposure Parameter | ||||
| kV Range | 40kV-125kV,1kV step | 40kV-125kV,1kV step | 40kV-125kV,1kV step | 40kV-125kV,1kV step |
| mA Range | 10-100mA | 10-100mA | 10-100mA | 10-140mA |
| ms Range | 1-4000ms | 1-4000ms | 1-4000ms | 2-2000ms |
| ms accuracy | ≤±(5%+0.2ms) | ≤±(5%+0.2ms) | ≤±(5%+0.2ms) | ≤±(5%+0.2ms) |
| mAs Range | 0.1-200mAs | 0.1-200mAs | 0.1-200mAs | 0.2-100mAs |
| mAs accuracy | ≤±(5%+0.2mAs) | ≤±(5%+0.2mAs) | ≤±(5%+0.2mAs) | ≤±(5%+0.2mAs) |
| Optional Parameter | ||||
| tech.mode | kV-mAs | kV-mAs | kV-mAs | kV-mAs |
| kV-mA-ms | kV-mA-ms | kV-mA-ms | kV-mA-ms | |
| Communication interface | RS-232 | RS-232 | RS-232 | RS-232 |
| Tube Parameter | ||||
| Max power | 5.3kW | 5.3kW | 5.6kW | 8kW |
| Focal spot | Small:0.6;Large:1.8 | Small:0.6;Large:1.8 | Small:0.6;Large:1.8 | Small:0.6;Large:2 |
| Exposure duty cycle | 1:60 | 1:60 | 1:60 | 1:60 |
| Maximum current of small filament | 20mA | 20mA | 20mA | 20mA |
| Maximum current of big filament | 100mA | 100mA | 100mA | 140mA |
| Leakage radiation loading factor | 125kv,0.24mA | 125kv,0.24mA | 125kv,0.24mA | 125kv,0.24mA |
| X-ray tube target angle | 15° | 15° | 15° | 15° |
| X-ray tube intrinsic filtration | 0.6mmAl | 0.6mmAl | 0.6mmAl | 0.6mmAl |
| Monoblock filtration | 1.5mmAl | 1.5mmAl | 1.5mmAl | 1.5mmAl |